SUDMEX TMS (ds003037)
SUDMEX TMS: The Mexican dataset of a repetitive transcranial magnetic stimulation clinical trial on cocaine use disorder patients
Longitudinal brain MRI of people with cocaine use disorder, collected in a randomized sham-controlled trial of repetitive transcranial magnetic stimulation (rTMS) with follow-up up to 12 months. 53 patients from Mexico City with structural, diffusion and resting-state scans, CC0.
Overview
SUDMEX TMS holds the brain MRI of a double-blind, placebo-controlled randomized trial at the National Institute of Psychiatry Ramón de la Fuente Muñiz in Mexico City (NCT02986438). The trial tested 5 Hz rTMS over the left dorsolateral prefrontal cortex as an add-on to usual treatment for cocaine use disorder (CUD), followed by an open-label maintenance phase. The images were released on OpenNeuro as ds003037 in 2020 under a CC0 waiver; the data descriptor appeared in Scientific Data in 2024 and describes snapshot 2.1.0. It is a sister dataset of SUDMEX CONN, scanned on the same scanner.
Composition
Snapshot 2.1.0 contains 53 patients and 156 MRI sessions. Every patient has a baseline session (T0). Follow-up sessions were planned after the two-week blinded phase (T1), at 3, 6 and 12 months (T2 to T4), and two weeks after T1 for sham patients who then chose open-label rTMS (T14). The participants table covers 50 patients with age (18 to 48), sex, arm (23 sham, 27 active), years of education and an exclusion flag that marks 6 of them. Clinical scales and cognitive tests for each study phase are published separately on Zenodo.
Acquisition
Scanning ran from 2017 to 2019 on one Philips Ingenia 3T with a 32-channel head coil, about 50 minutes per session. Each session had a 10-minute eyes-open resting-state EPI (TR 2 s, 300 volumes), a mostly 1 mm isotropic 3D T1-weighted scan and a multishell HARDI diffusion scan (b = 1000 and 2500 s/mm², b = 3000 for the first 4 patients), each EPI series with a reverse phase-encoded field map. Images are BIDS NIfTI, defaced with pydeface.
Annotations
There are no image annotations. CUD was diagnosed with the MINI-Plus interview. The paper reports MRIQC and EDDY QC metrics per session.
Known limitations
- The paper reports 54 patients (30 active, 24 sham) in the text and 53 (30 active, 23 sham) in Table 1; the release has 53 subject folders, and 3 of them have no participants.tsv row.
- Attrition is high: 45 patients have a T1 session, 15 a T3 and 7 a T4.
- 2 patients have a session labelled t5 that neither the README nor the paper describes.
- Some patients moved a lot during scanning; the authors recommend artifact correction.
Cohort
Aggregate numbers from the sources below. Bars are relative to the 53 subjects.
Sex
- Female 7 14%
- Male 43 86%
Covers 50 of 53 subjects.
sex in participants.tsv of ds003037 snapshot 2.1.0 (CC0), 50 rows; sex and age columns
Contrast / sequence
Groups can overlap
- T1-weighted 53 100%
- BOLD fMRI 53 100%
- Diffusion-weighted 52 98%
anat, func, dwi in File tree of ds003037 snapshot 2.1.0 (CC0), sessions with a T1w, dwi or bold NIfTI file
Scanner vendor
- Philips 53 100%
Magnetic resonance imaging acquisition in Angeles-Valdez et al. 2024, The Mexican dataset of a repetitive transcranial magnetic stimulation clinical trial on cocaine use disorder patients: SUDMEX TMS, Scientific Data
Age
mean 34.8 ± 7.7, median 35, range 18 to 48
age in participants.tsv of ds003037 snapshot 2.1.0 (CC0), 50 rows; sex and age columns
Condition
Groups can overlap
- Cocaine use disorder 53 100%
Methods, Participants in Angeles-Valdez et al. 2024, The Mexican dataset of a repetitive transcranial magnetic stimulation clinical trial on cocaine use disorder patients: SUDMEX TMS, Scientific Data
Field strength
- 3 T 53 100%
Magnetic resonance imaging acquisition in Angeles-Valdez et al. 2024, The Mexican dataset of a repetitive transcranial magnetic stimulation clinical trial on cocaine use disorder patients: SUDMEX TMS, Scientific Data
Age by sex
Reported cross table. Missing cells were not published (fewer than 10 or not reported).
- n/a40-4911
- n/a30-3920
- n/a20-2910
sex and age in participants.tsv of ds003037 snapshot 2.1.0 (CC0), 50 rows; sex and age columns
Contrast combinations
How many subjects have exactly each set of contrasts.
| T1w | dwi | bold | Subjects with exactly this set |
|---|---|---|---|
52 | |||
1 |
From File tree of ds003037 snapshot 2.1.0 (CC0), sessions with a T1w, dwi or bold NIfTI file
License and access
Our reading of the license, not legal advice. Before you use the data, read the original license and confirm that your use is allowed. We take no responsibility for how you use a dataset. Full disclaimer
Download without an account
Creative Commons Zero 1.0 Universal
Public domain dedication. Do anything with the data, including commercial use, without asking and without having to give credit.
dataset_description.json of snapshot 2.1.0 states "License" CC0. Clinical and cognitive data are published separately on Zenodo and are not covered by this entry.
What you can do
- Yes
- Yes
- Yes
- Yes
- Yes
What you can share
- Yes
- Yes
- Yes
What you must do
- No
- Share alike No
- No
- No
- Manuscript review No
- Release code No
- Return results No
- Delete after use No
Limits
- No
- Location limits No
Citation
Angeles-Valdez D, Rasgado-Toledo J, Villicaña V, et al. The Mexican dataset of a repetitive transcranial magnetic stimulation clinical trial on cocaine use disorder patients: SUDMEX TMS. Scientific Data 11, 408 (2024). doi:10.1038/s41597-024-03242-y
Sources
Every number on this page comes from one of these documents. Each chart names the table or page it is taken from. The raw numbers are in stats.csv.
- Angeles-Valdez et al. 2024, The Mexican dataset of a repetitive transcranial magnetic stimulation clinical trial on cocaine use disorder patients: SUDMEX TMS, Scientific Data paper
- OpenNeuro ds003037 snapshot 2.1.0 (dataset_description.json, README, CHANGES and snapshot summary) website
- participants.tsv of ds003037 snapshot 2.1.0 (CC0), 50 rows; sex and age columns computed
- File tree of ds003037 snapshot 2.1.0 (CC0), sessions with a T1w, dwi or bold NIfTI file computed