Washington University 120 (ds000243)
Washington University 120 (WU120)
Resting-state fMRI and T1-weighted brain MRI of healthy right-handed young adults, released with a study of how slice-timing interpolation alters head-motion estimates and artifact detection. 120 adults from Saint Louis, under CC0.
Overview
The Washington University 120 (WU120) set holds resting-state fMRI and a T1-weighted anatomical scan from 120 healthy young adults scanned by the Petersen/Schlaggar group in Saint Louis. Jonathan Power and colleagues released it alongside their 2017 PLoS One paper on how slice-timing correction (temporal interpolation) changes head-motion estimates and the detection of motion artifacts. It was first shared through OpenfMRI and is now OpenNeuro ds000243, organized in BIDS under a CC0 waiver.
Composition
All 120 participants were right-handed, reported English as their first language and had no significant neurological or psychiatric history. The participants table lists 61 women and 59 men aged about 18 to 32 (mean 24.7 years). Every subject has one MP-RAGE and one or two eyes-open resting-state runs (fixating a crosshair), 203 BOLD runs in total. The paper reports 346 ± 136 volumes per subject on average, about 14 minutes of rest data.
Acquisition
Scans were collected on a Siemens MAGNETOM Tim Trio 3T scanner with a 12-channel head matrix coil. The BOLD runs used an interleaved ascending echo-planar sequence with a repetition time of 2.5 s, an echo time of 27 ms and 4 mm isotropic voxels in 32 slices. The MP-RAGE sidecar gives a repetition time of 2.4 s and a flip angle of 8 degrees. The OpenfMRI curators defaced all anatomical images with pydeface; snapshot 1.0.0 (August 2025) re-defaced one subject's T1w. MRIQC quality metrics are included as derivatives.
Known limitations
- The 120 subjects were selected from about 200 Washington University scans because each keeps at least 120 low-motion volumes, so the set under-represents high-motion people.
- Rest duration differs between subjects (7.5 to 30 minutes in the participants table), since the scans were pooled from several studies.
- The cohort is narrow: young, right-handed, English-speaking adults without patients.
- There are no image annotations beyond the MRIQC outputs.
- The curators note that a paper describing the data mentions two subjects with a different TR, but the submitter confirmed that all shared runs use the same TR.
Cohort
Aggregate numbers from the sources below. Bars are relative to the 120 subjects.
Sex
- Female 61 51%
- Male 59 49%
From participants.tsv of ds000243 (CC0), counted per row from the Age and Gender columns
Contrast / sequence
Groups can overlap
- T1-weighted 120 100%
- BOLD fMRI 120 100%
Scanner vendor
- Siemens Healthineers 120 100%
Methods (WU cohort) in Power et al. 2017, Temporal interpolation alters motion in fMRI scans, PLoS One
Country
- United States 120 100%
Methods (WU cohort) in Power et al. 2017, Temporal interpolation alters motion in fMRI scans, PLoS One
Age
mean 24.7 ± 2.4, median 24.5, range 18.6 to 31.7
From participants.tsv of ds000243 (CC0), counted per row from the Age and Gender columns
Condition
Groups can overlap
- Healthy control 120 100%
README in OpenNeuro ds000243 snapshot 1.0.0 (README, dataset_description.json, sidecars and snapshot summary)
Field strength
- 3 T 120 100%
Methods (WU cohort) in Power et al. 2017, Temporal interpolation alters motion in fMRI scans, PLoS One
Age by sex
Reported cross table. Missing cells were not published (fewer than 10 or not reported).
- 6020-2955
From participants.tsv of ds000243 (CC0), counted per row from the Age and Gender columns
Contrast combinations
How many subjects have exactly each set of contrasts.
| T1w | bold | Subjects with exactly this set |
|---|---|---|
120 |
License and access
Our reading of the license, not legal advice. Before you use the data, read the original license and confirm that your use is allowed. We take no responsibility for how you use a dataset. Full disclaimer
Download without an account
Creative Commons Zero 1.0 Universal
Public domain dedication. Do anything with the data, including commercial use, without asking and without having to give credit.
dataset_description.json of snapshot 1.0.0 states "License" CC0.
What you can do
- Yes
- Yes
- Yes
- Yes
- Yes
What you can share
- Yes
- Yes
- Yes
What you must do
- No
- Share alike No
- No
- No
- Manuscript review No
- Release code No
- Return results No
- Delete after use No
Limits
- No
- Location limits No
Citation
Power JD, Plitt M, Kundu P, Bandettini PA, Martin A. Temporal interpolation alters motion in fMRI scans: Magnitudes and consequences for artifact detection. PLoS One 12(9):e0182939 (2017). doi:10.1371/journal.pone.0182939
Sources
Every number on this page comes from one of these documents. Each chart names the table or page it is taken from. The raw numbers are in stats.csv.
- Power et al. 2017, Temporal interpolation alters motion in fMRI scans, PLoS One paper
- OpenNeuro ds000243 snapshot 1.0.0 (README, dataset_description.json, sidecars and snapshot summary) website
- participants.tsv of ds000243 (CC0), counted per row from the Age and Gender columns computed
- File listing of the ds000243 repository (CC0), counting sub-*/anat/*_T1w.nii.gz and sub-*/func/*_bold.nii.gz computed