Skip to content
MRI Brain

CUHK SWI-CMB (public subset)

CUHK SWI cerebral microbleed dataset released with the 3D CNN microbleed detection paper (Dou et al. 2016)

Susceptibility-weighted brain MRI with point annotations of cerebral microbleeds, released so others can reproduce a 3D CNN microbleed detector or test their own. 20 subjects from a larger stroke and ageing set built at The Chinese University of Hong Kong.

Overview

This is the public part of SWI-CMB, a susceptibility-weighted MRI collection that a group at The Chinese University of Hong Kong built to train and test a cascaded 3D convolutional network for cerebral microbleed detection (Dou et al., IEEE TMI 2016). The full collection was not released; the project page offers an archive with 20 of the subjects and their microbleed annotations, released for others to reproduce the paper or to build and test their own detectors.

Composition

The archive holds 20 SWI volumes in NIfTI format and one MATLAB file per subject with the voxel coordinates of the centroid of each annotated microbleed. The readme does not say which of the paper's groups or splits the 20 subjects come from.

The full SWI-CMB set in the paper has 320 subjects: 126 with stroke (mean age 67.4 ± 11.3 years) and 194 from a normal ageing group (mean age 71.2 ± 5.0 years), with 1,149 annotated microbleeds in total. The paper split it at random into 230 training, 40 validation and 50 test subjects.

Acquisition

All scans come from a single 3.0 T Philips system with a 3D spoiled gradient-echo sequence (repetition time 17 ms, echo time 24 ms), a 512 × 512 × 150 matrix, 0.45 × 0.45 mm in-plane resolution, 2 mm slices at 1 mm spacing and a 230 × 230 mm field of view.

Annotations

One experienced rater labelled the microbleeds and a neurologist verified them, following the Microbleed Anatomical Rating Scale (MARS). Agreement between the two, checked on 20 subjects, gave a Pearson correlation of 0.91. Labels are points (lesion centroids), not voxel masks, and only microbleeds are annotated.

Known limitations

  • Only 20 of the 320 subjects are public, which suits evaluation rather than training.
  • One site, one scanner and one protocol.
  • No demographic or clinical data come with the released files.
  • The terms in the archive's readme limit use to research and reserve all other rights to the university; the project page states no terms.

Cohort

Aggregate numbers from the sources below. Bars are relative to the 20 subjects.

Contrast / sequence

Groups can overlap

  • Susceptibility-weighted 20 100%

Section III-A in Dou et al. 2016, IEEE Transactions on Medical Imaging (author copy on the CUHK site)

License and access

Our reading of the license, not legal advice. Before you use the data, read the original license and confirm that your use is allowed. We take no responsibility for how you use a dataset. Full disclaimer

Access
Open download

Download without an account

Access page

CUHK 3D CNN cerebral microbleed code and data release terms (readme.txt)

Not a formal license. A short notice in the data archive reserves all rights to The Chinese University of Hong Kong, releases the code and data for research only, asks users to cite the TMI 2016 paper and to contact the authors about any commercial use.

The terms are stated in readme.txt inside the data archive. The project page itself states no license.

Original license text Version read: readme.txt in cmb-3dcnn-data.zip (archive dated 2016-04-28), read 2026-10-08 Checked 2026-10-08

What you can do

  • No
  • Conditional
  • Conditional
  • Not stated
  • Yes

What you can share

  • No
  • Share derived data Not stated
  • Share trained models Not stated

What you must do

  • Yes
  • Share alike No
  • No
  • No
  • Manuscript review No
  • Release code No
  • Return results No
  • Delete after use No

Limits

  • No
  • Location limits No

Citation

Dou Q, Chen H, Yu L, Zhao L, Qin J, Wang D, Mok VC, Shi L, Heng PA. Automatic Detection of Cerebral Microbleeds From MR Images via 3D Convolutional Neural Networks. IEEE Transactions on Medical Imaging 35(5), 1182-1195 (2016). doi:10.1109/TMI.2016.2528129

Sources

Every number on this page comes from one of these documents. Each chart names the table or page it is taken from. The raw numbers are in stats.csv.