Skip to content
X-ray (computed radiography) CT X-ray MRI SPECT / nuclear medicine PET AbdomenChestLung

COVID-19-NY-SBU

Stony Brook University COVID-19 Positive Cases

Clinical imaging of 1,384 PCR-positive COVID-19 patients from Stony Brook Medicine, mostly portable chest radiographs plus chest and abdominal CT and a few MRI, PET and nuclear medicine studies, linked to OMOP-based clinical data on outcomes, ICU stay and ventilation.

Overview

COVID-19-NY-SBU is a collection of routine clinical images from adults who tested PCR positive for COVID-19 at Stony Brook Medicine in New York, released through The Cancer Imaging Archive in 2021. Each patient is linked to a row of clinical data drawn from the hospital's COVID Data Commons, so the collection is mainly used to build diagnostic and prognostic models that combine chest imaging with outcomes such as death, ICU admission or mechanical ventilation.

Composition

The release covers 1,384 patients, 7,361 studies and 17,950 series. Chest radiographs dominate: 1,343 patients have computed radiography and 157 have digital radiography, most of them portable AP chest views, with some abdominal films. 458 patients have CT, mainly chest CT with and without contrast, CT pulmonary angiography and abdomen-pelvis CT. A handful of patients have abdominal MRI, FDG PET/CT or nuclear medicine lung perfusion scans.

The clinical table has one row per patient for a single encounter, chosen as the most severe COVID-positive visit. It holds demographics, comorbidities, symptoms at admission, first lab and vital values, ICU stay, ventilation and discharge status, coded to the OMOP Common Data Model with LOINC codes for labs. In that table, 183 patients died and 1,201 were discharged; 260 were in the ICU and 213 were ventilated. Ages are only given in three bins (18 to 59, 60 to 74, 75 to 90).

Acquisition

Images were exported from the Stony Brook radiology PACS and de-identified with POSDA. Dates are shifted, and the clinical encounter date uses the same shift so images can be aligned with the selected visit. Radiographs come from Carestream systems; CT scanners are from GE, Toshiba and Siemens.

Annotations

There are no image-level labels or segmentations. Targets come from the clinical table (outcome, ICU, ventilation, lab values).

Known limitations

  • Single center, and only COVID-positive patients, so there is no negative control group.
  • Imaging is whatever was ordered in care, so the number and timing of studies differ widely between patients.
  • Clinical values cover one selected encounter only; many fields are missing (NA).
  • Sex differs slightly between the clinical table and the DICOM headers.
  • The collection summary mentions brain MRI, but the MR series in the release metadata are all abdominal.

Cohort

Aggregate numbers from the sources below. Bars are relative to the 1,384 subjects.

Sex

  • Male 760 55%
  • Female 592 43%
  • Unknown 32 2%

Age

0
200
400
600
765
18-5960-7475-90

Modality

subjects

  • X-ray (computed radiography) 1,343 97%
  • CT 458 33%
  • X-ray 157 11%
  • SPECT / nuclear medicine 5 <1%
  • MRI 4 <1%
  • PET 4 <1%

Condition

subjects, values can overlap

  • COVID-19 1,384 100%

Scanner vendor

subjects

  • Carestream 1,365 99%
  • GE HealthCare 363 26%
  • Canon Medical 132 10%
  • Siemens Healthineers 10 <1%

License and access

Our reading of the license, not legal advice. Before you use the data, read the original license and confirm that your use is allowed. We take no responsibility for how you use a dataset. Full disclaimer

Access
Open download

Download without an account

Images download with the TCIA Data Retriever; the clinical CSV and its field template download directly.

Access page

Creative Commons Attribution 4.0 International

Use, share and adapt the data for any purpose, including commercial use, as long as you credit the creators.

TCIA lists the images, the clinical data and the clinical data template under CC BY 4.0. Users must also agree to the TCIA Data Usage Policy, which says users must "Not use the requested datasets, either alone or in concert with any other information, to identify or contact individual participants" and requires citing the dataset DOI (https://www.cancerimagingarchive.net/data-usage-policies-and-restrictions/).

Original license text Version read: 4.0 Checked 2026-10-07

What you can do

  • Yes
  • Yes
  • Yes
  • Yes

What you can share

  • Yes
  • Yes
  • Yes

What you must do

  • Yes
  • Share alike No
  • No
  • No
  • Manuscript review No
  • Release code No
  • Return results No
  • Delete after use No

Limits

  • No
  • Location limits No

Citation

Saltz J, Saltz M, Prasanna P, Moffitt R, Hajagos J, Bremer E, Balsamo J, Kurc T. (2021). Stony Brook University COVID-19 Positive Cases [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/TCIA.BBAG-2923

All numbers

Every number on this page, as stored in stats.csv, with its source.

MeasureBreakdownValueSource
Subjectstotal 1,384tcia-covid-19-ny-sbu
Data Access table
Studiestotal 7,361tcia-covid-19-ny-sbu
Data Access table
Imagestotal
DICOM instances over all modalities in 17950 series
562,376tcia-covid-19-ny-sbu
Data Access table
Subjectscondition=covid19
All patients PCR positive
1,384tcia-covid-19-ny-sbu
Summary
Subjectsmodality=CR 1,343sbu-nbia-digest
Modality column, Patient ID column
Subjectsmodality=DX 157sbu-nbia-digest
Modality column, Patient ID column
Subjectsmodality=CT 458sbu-nbia-digest
Modality column, Patient ID column
Subjectsmodality=MR 4sbu-nbia-digest
Modality column, Patient ID column
Subjectsmodality=PT 4sbu-nbia-digest
Modality column, Patient ID column
Subjectsmodality=NM 5sbu-nbia-digest
Modality column, Patient ID column
Studiesmodality=CR 5,526sbu-nbia-digest
Modality column, Study Instance UID column
Studiesmodality=DX 1,214sbu-nbia-digest
Modality column, Study Instance UID column
Studiesmodality=CT 617sbu-nbia-digest
Modality column, Study Instance UID column
Studiesmodality=MR 4sbu-nbia-digest
Modality column, Study Instance UID column
Studiesmodality=PT 5sbu-nbia-digest
Modality column, Study Instance UID column
Studiesmodality=NM 5sbu-nbia-digest
Modality column, Study Instance UID column
Imagesmodality=CR
One image per series
11,509sbu-nbia-digest
Modality column, Image Count column
Imagesmodality=DX
One image per series
2,623sbu-nbia-digest
Modality column, Image Count column
Scansmodality=CT 3,730sbu-nbia-digest
Modality column, one row per series
Scansmodality=MR 48sbu-nbia-digest
Modality column, one row per series
Scansmodality=PT 12sbu-nbia-digest
Modality column, one row per series
Scansmodality=NM 20sbu-nbia-digest
Modality column, one row per series
Subjectsvendor=carestream
All CR and DX series
1,365sbu-nbia-digest
Manufacturer column, Patient ID column
Subjectsvendor=ge 363sbu-nbia-digest
Manufacturer column, Patient ID column
Subjectsvendor=canon
Manufacturer TOSHIBA
132sbu-nbia-digest
Manufacturer column, Patient ID column
Subjectsvendor=siemens
Includes SIEMENS NM
10sbu-nbia-digest
Manufacturer column, Patient ID column
Subjectssex=male 760sbu-clinical-csv
gender_concept_name column
Subjectssex=female 592sbu-clinical-csv
gender_concept_name column
Subjectssex=unknown
Value NA
32sbu-clinical-csv
gender_concept_name column
Subjectsage=18-59
Source bin [18,59]
765sbu-clinical-csv
age.splits column
Subjectsage=60-74
Source bin (59,74]
350sbu-clinical-csv
age.splits column
Subjectsage=75-90
Source bin (74,90]
269sbu-clinical-csv
age.splits column

Sources

The keys used in the table above.