ACRIN-Contralateral-Breast-MR

ACRIN-Contralateral-Breast-MR (ACRIN 6667)

Contrast-enhanced breast MRI of 984 women with recently diagnosed unilateral breast cancer from the multicenter ACRIN 6667 trial, which screened the contralateral breast for occult cancer, with clinical, pathology and follow-up forms.

Overview

ACRIN-Contralateral-Breast-MR contains the breast MRI and clinical forms of ACRIN 6667, a multicenter trial of the American College of Radiology Imaging Network. It tested whether MRI finds cancer in the opposite breast of women whose unilateral breast cancer had just been diagnosed and whose other breast looked normal on mammography and clinical examination. The trial reported that MRI found occult contralateral cancer in 30 of 969 analyzed women, with 91% sensitivity and 88% specificity. The Cancer Imaging Archive released the collection in 2021 under CC BY 4.0. It fits work on lesion detection and malignancy classification in contrast-enhanced breast MRI.

Composition

The collection has 984 women aged 25 to 86 (mean 53.2, median 53), with 1,103 imaging studies, 10,184 DICOM series and 626,782 images. Only 969 women met the criteria for the primary analysis. Most women have a single MRI study; some have repeat studies from the follow-up work-up of suspicious findings. One series is a computed radiography (CR) image; all others are MR. Clinical data come as one CSV per trial form with a data dictionary, covering imaging, clinical management, pathology and outcome. Dates are shifted so that each woman's study entry falls on 1 January 1960, which keeps the intervals between events intact.

Acquisition

The protocol required a magnet of at least 1.5 T, a dedicated breast coil, and at least one pre-contrast and two post-contrast 3D T1-weighted gradient echo acquisitions, with the first post-contrast scan within 4 minutes of injection. Slices were at most 3 mm thick, with fat suppression or subtraction. Sites could otherwise use their own protocol, and series descriptions show additional T2-weighted and localizer series in many exams. Scanners are mostly GE, Siemens and Philips systems; some series were produced by computer-aided detection software.

Annotations

No image annotations are distributed. MRI findings, biopsy outcomes and the reference standard (biopsy or one year of follow-up) are recorded in the clinical forms, not as image masks or coordinates.

Known limitations

  • The image data of case 120 were removed because they were corrupt; its clinical records remain.
  • A missing DICOM Sequence Variant tag was filled with the placeholder value NONE.
  • The cancer prevalence in the screened breast is low, so positive cases are few.
  • Field strength and exact sequence parameters vary by site and are not summarized on the collection page.

Cohort

Aggregate numbers from the sources below. Bars are relative to the 984 subjects.

Sex

  • Female 984 100%

Age

mean 53.2± 11 · range 25 to 86

No age bins reported.

Condition

subjects, values can overlap

  • Breast cancer 984 100%

Scanner vendor

subjects

  • GE HealthCare 492 50%
  • Siemens Healthineers 287 29%
  • Philips 177 18%

License and access

Our reading of the license, not legal advice. Before you use the data, read the original license and confirm that your use is allowed. We take no responsibility for how you use a dataset. Full disclaimer

Access
Open download

Download without an account

The images are downloaded with a TCIA manifest file and the NBIA Data Retriever, or through the NCI Imaging Data Commons. The clinical CSV files are a direct download from the collection page. No account is needed.

Access page

Creative Commons Attribution 4.0 International

Use, share and adapt the data for any purpose, including commercial use, as long as you credit the creators.

Original license text Version read: 4.0 Checked 2026-10-07

What you can do

  • Yes
  • Yes
  • Yes
  • Yes

What you can share

  • Yes
  • Yes
  • Yes

What you must do

  • Yes
  • Share alike No
  • No
  • No
  • Manuscript review No
  • Release code No
  • Return results No
  • Delete after use No

Limits

  • No
  • Location limits No

Citation

Kinahan P, Muzi M, Bialecki B, Herman B, Coombs L. (2021). ACRIN-Contralateral-Breast-MR (ACRIN 6667) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/Q1EE-J082. Publication: Lehman CD, Gatsonis C, Kuhl CK, et al. MRI evaluation of the contralateral breast in women with recently diagnosed breast cancer. N Engl J Med 356:1295-1303 (2007). https://doi.org/10.1056/NEJMoa065447

All numbers

Every number on this page, as stored in stats.csv, with its source.

MeasureBreakdownValueSource
Subjectstotal
969 of them were included in the trial's primary analysis
984tcia-acrin-contralateral-breast-mr
Data Access table
Studiestotal 1,103tcia-acrin-contralateral-breast-mr
Data Access table
Scanstotal
DICOM series, MR and CR
10,184tcia-acrin-contralateral-breast-mr
Data Access table
Imagestotal
DICOM images (slices)
626,782tcia-acrin-contralateral-breast-mr
Data Access table
Subjectssex=female 984tcia-acrin-contralateral-breast-mr
Demographic Summary of Available Imaging
Subjectscondition=breast_cancer
all women had recently diagnosed unilateral breast cancer
984tcia-acrin-contralateral-breast-mr
Detailed Description
Mean agetotal 53.2tcia-acrin-contralateral-breast-mr
Demographic Summary of Available Imaging
Age SDtotal 11tcia-acrin-contralateral-breast-mr
Demographic Summary of Available Imaging
Median agetotal
interquartile range 45 to 60
53tcia-acrin-contralateral-breast-mr
Demographic Summary of Available Imaging
Minimum agetotal 25tcia-acrin-contralateral-breast-mr
Demographic Summary of Available Imaging
Maximum agetotal 86tcia-acrin-contralateral-breast-mr
Demographic Summary of Available Imaging
Subjectsvendor=ge
subjects with at least one series from this vendor
492tcia-acrin-6667-digest
Patient ID, Manufacturer
Subjectsvendor=siemens
subjects with at least one series from this vendor
287tcia-acrin-6667-digest
Patient ID, Manufacturer
Subjectsvendor=philips
subjects with at least one series from this vendor
177tcia-acrin-6667-digest
Patient ID, Manufacturer

Sources

The keys used in the table above.